Substrate
-
Sloping screed (>1 / max. 5%)
-
Vapour barrier with VELOBIT 3 mm membrane, totally bonded
on the verticals.
-
Insulation panel.
-
Double layer waterproofing system, made of:
a) first layer: NOVABOND 4 mm, loose laid on the horizontal
surface and fully bonded on the verticals up to a height of 15
cm above the level of the soil. Overlaps must be torched respectively
8 cm at the side and 12 cm at the end.
b) second layer: NOVAR-WS anti-root membrane, FLL
certified, 4 mm thickness, totally bonded by torching on the first
layer and on the verticals.
The membrane must be laid in such way that the side overlapping
areas are positioned in the centre line of the first layer. Overlaps
must be torched respectively 12 cm at the side and 15 cm at the
end.
-
Protective layer made with 0.2 mm thick polyethylene film or 400
gr/sqm non woven material.
-
Drainage layer made of expanded clay or gravel
-
Filtering layer of compact non woven 200 gr/sqm material.
-
Layer of soil.
|
|
|
|